Bird-technologies 6156 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Bird-technologies 6156. Bird Technologies 6156 Manuale d'uso Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 34
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
INSTRUCTION BOOK
OPERATING INSTRUCTIONS
TERMALINE
®
WATTMETTER
MODELS 6104, 6154, 6156
©Copyright 1998 by
Bird Electronic Corporation
Instruction Book Part Number 920-6104/54-56 Revision A
Termaline
®
and Thruline
®
are Registered Trademarks
of Bird Electronic Corporation
Electronic Corporation
Cleveland (Solon) Ohio US
A
Vue de la page 0
1 2 3 4 5 6 ... 33 34

Résumé du contenu

Page 1 - MODELS 6104, 6154, 6156

INSTRUCTION BOOKOPERATING INSTRUCTIONSTERMALINE®WATTMETTERMODELS 6104, 6154, 6156©Copyright 1998 byBird Electronic CorporationInstruction Book Part Nu

Page 2

Measuring Transmitter Power. ...10Dummy Antenna. ...11Maintenance. ...13Troubleshooting...

Page 4

xBird Model 6104/54/56 Termaline WattmeterFigure 1Models 6154 and 6156

Page 5

Chapter 1IntroductionPurpose andFunctionThis instruction book is intended for use by operators of theModels 6104, 6154 and 6156 Termaline Wattmeters.

Page 6

Specifications2Bird Model 6104/54/56 Termaline WattmeterImpedance 50 ohms nominalVSWR 1.10:1 maximum across unit frequencyrange, with Female “N” conn.

Page 7 - About This Manual

Chapter 2Theory Of OperationThe method of power determination used in the TermalineWattmeter may be expressed as W=E2/R where E is thevoltage across t

Page 8

tank is encased in a set of metal radiating fins, which arefirmly pressed on the cylinder. The heat from the dielectricoil is transferred to the surro

Page 9 - Table of Contents

Chapter 3InstallationThis chapter provides information for preparing the Models6104, 6154, and 6156 for use.Location Free air circulation around the w

Page 10

above the notch on the hook. Use a flatblade screwdriver.2. Pull the housing straight off of the ra-diator.3. Place the meter in a convenient loca-tio

Page 11

TransmitterConnectionConnection to the transmitter is made through a suitablecoaxial cable equipped with appropriate RF connectors.Keep the length of

Page 13 - Introduction

8Bird Model 6104/54/56 Termaline WattmeterZero Adjust ScrewFigure 4Zero Adjust

Page 14 - Specifications

Chapter 4Operating InstructionsWARNINGNever attempt to connect or disconnect equipmentfrom the transmission line while RF power is beingapplied. Leaki

Page 15 - Theory Of Operation

CAUTIONThe diode assembly is an ESD sensitive assembly, use proper ESDprecautions.MeasuringTransmitterPower1. Place the wattmeter in a positionwhere t

Page 16

DummyAntennaThe Wattmeter may be used as a 50 ohm coaxial termina-tion for transmitters with a power output up to 80 or 150 Wrespectively from dc to 4

Page 17 - Installation

12Bird Model 6104/54/56 Termaline Wattmeter

Page 18 - Operation

Chapter 5MaintenanceThis chapter covers the cleaning, inspection, troubleshoot-ing, and replacement parts.TroubleshootingThe troubleshooting table bel

Page 19 - Connection

InspectionPeriodic inspection is necessary at about six month inter-vals. Inspection should include the following items.Oil Leakage Check for coolant

Page 20 - Zero Adjust Screw

3. Disconnect the dc plug from the volt-meter block.4. Place the load in a vertical positionwith the voltmeter up.5. Loosen the 8-32 x 1 inch screw fr

Page 21 - Operating Instructions

2. Remove the dc cable and terminalstrip from the meter by loosening thetwo 8-32 hex nuts on the meter termi-nals.3. Place the meter face down on a sm

Page 22 - Measuring

17MaintenanceBend Braid Back5/16 Typ.3/167/325/32Figure 6DC CableAssemblyLOCKING RING15/32 HEXNUTRED15/32 HEXNUTBLK15/32 INT. LOCKWASHER321Figure 5Swi

Page 23

Safety PrecautionsGeneral Safety StatementsThe following are general safety precautions that are not necessarily relatedto any specific part or proced

Page 24

2. To assemble the cable, RG58/U, to thedc plug, slip the bushing, washer, andgrommet over the end of the cable. Re-fer to figure 6.3. Remove the oute

Page 25 - Maintenance

cleaner that is self-drying, and does not leave a residue onthe inaccessible internal parts.Customer ServiceBird Electronic Corporation30303 Aurora Ro

Page 26

Models 6154 & 615620Bird Model 6104/54/56 Termaline WattmeterQty. Description Part Number1Resistor voltmeter assembly (calibrated) 6154-002-11Radi

Page 27 - Replacement

21Limited WarrantyAll products manufactured by Seller are warranted to be free from defects inmaterial and workmanship for a period of one (1) year, u

Page 28

22DECLARATION OF CONFORMITYManufacturer: Bird Electronic Corporation30303 Aurora RoadCleveland, Ohio 44139-2794Product: Termaline Coaxial Load Resisto

Page 29 - 5/16 Typ

CAUTIONCaution notes call attention to a procedure, which if not performedcorrectly, could result in damage to the equipment.This symbol appears on th

Page 30 - Assembly

Safety StatementsUSAGEANY USE OF THIS INSTRUMENT IN A MANNER NOTSPECIFIED BY THE MANUFACTURER MAY IMPAIRTHE INSTRUMENT’S SAFETY PROTECTION.USOEL USO D

Page 31

WARTUNGANWEISUNGEN FÜR DIE WARTUNG DES GERÄTESGELTEN NUR FÜR GESCHULTES FACHPERSONAL.ZUR VERMEIDUNG GEFÄHRLICHE, ELEKTRISCHESCHOCKS, SIND WARTUNGSARBE

Page 32

About This ManualThis instruction book covers the model 6104, 6154, and 6156 Termaline RFWattmetersThis instruction book is arranged so that the essen

Page 33 - Limited Warranty

viBird Model 6104/54/56 Termaline Wattmeter

Page 34 - DECLARATION OF CONFORMITY

Table of ContentsSafety Precautions. ......iWarning Statement .....iiCaution Statements. .....iiSafety Stateme

Modèles reliés 6154 | 6104 |

Commentaires sur ces manuels

Pas de commentaire