Bird-technologies 4201 Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Bird-technologies 4201 Series. Bird Technologies 4201 Series User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 27
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
INSTRUCTION BOOK
OPERATING INSTRUCTIONS
SERIES 4201 MULTI-CHANNEL
RF DIRECTIONAL
THRULINE
®
WATTMETER
©
Copyright 1997 by Bird Electronic Corporation
Instruction Book Part Number 920-4201S Revision A
Thruline
®
is a Registered Trademark
of Bird Electronic Corporation
Electronic Corporation
Cleveland (Solon) Ohio US
A
Vue de la page 0
1 2 3 4 5 6 ... 26 27

Résumé du contenu

Page 1 - Electronic Corporation

INSTRUCTION BOOKOPERATING INSTRUCTIONSSERIES 4201 MULTI-CHANNELRF DIRECTIONALTHRULINE®WATTMETER©Copyright 1997 by Bird Electronic CorporationInstructi

Page 2

Models 4201A501 and 4201A502. ... 10Models 4201A503 and 4201A504. ... 10VSWR Conversion Nomograph. ...

Page 3 - Safety Precautions

Chapter 1IntroductionWattmeterPurpose andFunctionThe 4201 Series Multi-Channel RF Directional Wattmeter is used in conjunctionwith Bird Power Sensors,

Page 4

SpecificationsModels: 4201A501,4201A502Models: 4201A503,4201A504Items Required But Not SuppliedModels: 4201A501,4201A502Line Section: 4230-053 or 4522

Page 5

+ +Models 4201A501 and 4201A503Models 4201A502 and 4201A504++SENSOR INPUTS321456DISABLE12 CHANNEL RF POWER METERENABLE111210879MODEL 4201FWD1580F.S. =

Page 6

Power SensorsPower Sensors, for use with Models 4201A503 and 4201A504 Series Wattmeters,currently available are listed below.SpecificationsModel FWD M

Page 7 - About This Manual

Chapter 2InstallationThis chapter provides information for on site requirements, unpacking, inspection,and preparing the equipment for use.The 4201 Se

Page 8

2. If you are using power sensors, attach the cables to thepower sensors. Attach the forward meter cable to the for-ward feed-thru on the power sensor

Page 9 - Table Of Contents

On the top of the module, the sensor connections are labeled. The inputs are on therear of the module. Models 4201A502 and 4201A504 have 12 sets of ph

Page 10

Bird Series 4201 Multi-Channel RF Directional Wattmeter8

Page 11 - Introduction

Chapter 3Operating InstructionsA description of all operator controls and indicators are provided in this chapter.Read and become familiar with the fo

Page 13 - Models 4201A502 and 4201A504

Zeroing MetersBefore any power measurements are made, be sure the pointer rests on the zeromark. If not, adjust the zero adjustment screw clockwise or

Page 14 - Power Sensors

VSWR ConversionNomographUsing the VSWR Nomograph, determine the intersection of the forward and reflectedpower values. The slanted line passing closes

Page 15 - Installation

Bird Series 4201 Multi-Channel RF Directional Wattmeter12

Page 16 - Phono Connector

Chapter 4MaintenanceGeneral This chapter includes cleaning, inspection, troubleshooting, and performance infor-mation.The Wattmeter Models 4201A501, 4

Page 17 - SENSOR CONNECTIONS

TroubleshootingUse the following table to aid in isolating problems, their cause, and possiblecorrections.Replacement PartsThis section provides the u

Page 18

CleaningThe outside surface of the unit may be cleaned occasionally with a soft clothdampened with a mild detergent solution.Clean the connectors freq

Page 19 - Operating Instructions

1. Remove the meter from the rack by removing the four screwsholding the panel in place.2. Remove the leads from the meter, make a note of thelocation

Page 20 - Using The Wattmeter

Limited WarrantyAll products manufactured by Seller are warranted to be free from defects in material and workmanshipfor a period of one (1) year, unl

Page 21 - Figure 10

Safety PrecautionsGeneral Safety PrecautionsThe following are general safety precautions that are not necessarily related to any specific part or proc

Page 22

USAGEANY USE OF THIS INSTRUMENT IN A MANNER NOT SPECIFIED BY THEMANUFACTURER MAY IMPAIR THE INSTRUMENT’S SAFETY PROTECTION.USOEL USO DE ESTE INSTRUMEN

Page 23 - Maintenance

ASSISTENZA TECNICALE ISTRUZIONI RELATIVE ALL’ASSISTENZA SONO PREVISTE ESCLUSI-VAMENTE PER IL PERSONALE OPPORTUNAMENTE ADDESTRATO. PER EVI-TARE PERICOL

Page 24 - Replacement Parts

Bird Series 4201 Multi-Channel RF Directional Wattmeteriv

Page 25 - Cable Replacement

About This ManualThis instruction book covers the Series 4201 Multi-Channel RF Directional Wattmeters. Specifically, theModels 4201A501, 4201A502, 420

Page 26 - Interconnecting

Bird Series 4201 Multi-Channel RF Directional Wattmetervi

Page 27 - Limited Warranty

Table Of ContentsSafety Precautions. .........iWarning Statements. .........iiCaution Statements.

Commentaires sur ces manuels

Pas de commentaire