Transmitter Power Monitor/Meter
Operations Manual
Model TPM series
&
3140A Power Meter Panel
The information within this manual is as complete as possible at the time of
printing. Bird Electronic Corporation is not liable for errors. Specifications,
limits, and text are subject to change without notice.
©Copyright 2008 by Bird Electronic Corporation
Instruction Book Part Number 920-TPM Rev. B
Microsoft and Windows are registered trademarks
of the Microsoft Corporation
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - 3140A Power Meter Panel

Transmitter Power Monitor/MeterOperations ManualModel TPM series&3140A Power Meter PanelThe information within this manual is as complete as possi

Page 3 - Caution Statements

Introduction1Chapter 1 IntroductionThe Transmitter Power Monitor (TPM) is the latest broadcast solution from Bird. Calibrated coupling ports and accur

Page 4

Bird Electronics Corporation2

Page 5 - Safety Statements

Installing & Operating Instructions - TPM3Chapter 2 Installing & Operating Instructions - TPM Note: The label on the top of the unit identi

Page 6

Bird Electronics Corporation4Installing the TPMThe TPM has two RF connectors (Source and Load) that connect to the transmission line, three test port

Page 7

Installing & Operating Instructions - TPM5Normal Operation Note: Coupler ports must be terminated to ensure accurate power measurements. Termin

Page 8 - Contents

Bird Electronics Corporation6

Page 9 - Table of Contents

Installing & Operating Instructions - 3140A Panel7Chapter 3 Installing & Operating Instructions - 3140A PanelThe 3140A is the standard display

Page 10

Bird Electronics Corporation8Installing the Panel1. Place panel in an empty slot on the rack and attach with mounting screws (optional).2. Connect the

Page 11 - Purpose and Function

Calibration9Chapter 4 CalibrationEvery calibration procedure will finish by providing a table of voltages that correspond to power levels at the calib

Page 12 - Bird Electronics Corporation

Safety PrecautionsThe following are general safety precautions that are not necessarily related to any specific part or procedure, and do not necessar

Page 13 - Figure 1

Bird Electronics Corporation10Passive CalibrationCalibrate the TPM on the transmitter it is monitoring. Also a refer-ence power meter is needed to mea

Page 14 - Installing the TPM

Calibration11Active CalibrationThe active method will recalibrate the TPM completely. This proce-dure will void the calibration and accuracy specifica

Page 15

Bird Electronics Corporation12Figure 8 Calibration Data CardTransmitter FrequencyFwd Coupling Offset at 195 MHzRfl Coupling Offset at 195 MHz

Page 16

Performance Specifications13Chapter 5 Performance SpecificationsTransmitter Power Meter (TPM)Model Naming Table Note: Models TPM 3 x - LV and model

Page 17 -  Note: 3140A8 shown

Bird Electronics Corporation14 * - Peak to Average ratio is specified based on the fullscale power of the specific TPM model. For example, a TPM wit

Page 18 - Installing the Panel

Performance Specifications15Interface SpecsMain line Diameters and center conductor setbacks per Bird drawings. Connectors One DB9(M), three N(F) DB

Page 19 - Zero Calibrating

Bird Electronics Corporation16DimensionsFigure 9 TPM7Figure 10 Unflanged 1-5/8” TPMFigure 11 Flanged 1-5/8” TPM

Page 20 - Passive Calibration

Performance Specifications17Figure 12 Unflanged 3-1/8” TPMFigure 13 Flanged 3-1/8” TPM

Page 21 - Active Calibration

Bird Electronics Corporation183140A Meter PanelGeneral SpecsFunction Provide power to multiple TPM units. Display Fwd and Rfl readings from one of th

Page 22 - Data Card

Maintenance19Chapter 6 MaintenanceInspection and CleaningThis unit requires only simple and routine maintenance.1. Wipe off dust and dirt regularly. U

Page 23 - Transmitter Power Meter (TPM)

iSafety Symbols Note: Calls attention to supplemental information.Warning StatementsThe following safety warnings appear in the text where there is

Page 24

Bird Electronics Corporation2061/8"100100010000r (kW)Line Section Max Power vs. Frequency6-1/84-1/16" & 4-1/2"3-1/8"1-5/8"

Page 25 - Line Size Weight, Max

Maintenance21TroubleshootingThe TPM has no operator serviceable parts. Any required service must be performed at an authorized service facility.The ta

Page 26 - Dimensions

Bird Electronics Corporation22Parts ListCustomer Replacement Part Consists of DescriptionRPK7006B112 - Replacement Digital Board 7006B112 Digital PC B

Page 27 - Performance Specifications

Maintenance23Declaration of ConformityManufacturer: Bird Technologies Group 30303 Aurora Road Cleveland, Ohio 44139-2794Type Product: Panel Meter: 314

Page 28 - 3140A Meter Panel

Bird Electronics Corporation24Customer ServiceIf you need to return the unit prior to use, please contact the Bird Technologies Sales department.For a

Page 29 - Inspection and Cleaning

25Limited WarrantyAll products manufactured by Seller are warranted to be free from defects in material and workmanship for a period of one year, unle

Page 30

Bird Technologies26

Page 31 - Troubleshooting

iiRefer to page 9.Refer to page 19.CAUTIONA Bird Calibration Kit is recommended for this procedure. Performing a calibration with anything other than

Page 32 - Parts List

iiiSafety StatementsUSAGEANY USE OF THIS INSTRUMENT IN A MANNER NOT SPECIFIED BY THE MANUFACTURER MAY IMPAIR THE INSTRUMENT’S SAFETY PROTECTION.USOEL

Page 33 - Declaration of Conformity

ivSERVICESERVICING INSTRUCTIONS ARE FOR USE BY SERVICE - TRAINED PERSONNEL ONLY. TO AVOID DANGEROUS ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING UNLES

Page 34 - Customer Service

vRF VOLTAGE MAY BE PRESENT IN RF ELEMENT SOCKET - KEEP ELEMENT IN SOCKET DURING OPERATION.DE LA TENSION H.F. PEAT ÊTRE PRÉSENTE DANS LA PRISE DE L&apo

Page 35 - Limited Warranty

viAbout This ManualThis manual covers the operating and maintenance instructions for the following models:Changes to this ManualWe have made every eff

Page 36 - Bird Technologies

viiTable of ContentsSafety Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iWarning Statements . . . . . .