Installing & Operating Instructions - TPM
3
Chapter 2 Installing & Operating Instructions - TPM
Note: The label on the top of the unit identifies the
connectors and ports. They are defined as follows:
Note: TPM units are terminated at the time of assembly.
SOURCE
Connect to the source of the RF signal
(transmitter side)
LOAD
Connect to the load of the RF signal
(antenna/dummy load)
FORWARD
The forward directional coupler port. Terminate
this port in 50 ohms at all times.*
REFLECTED
The reflected directional coupler port. Terminate
this port in 50 ohms at all times.*
TEST
A non directional sample port. No termination is
required.
* - If these ports are not terminated in 50 ohms, power
measurements will not be accurate.
To Source
Operation LED
Calibration Cover
FWD Port
RFL
Port
Test
Port
Calibration Cover
Note: Figure shown with terminations assembled.