Complementatry Cumulative Distribution Function (CCDF)
Physical and Environmental Specifications
ROHS
Measurement Uncert. Linear sum of peak and average
power uncertainty
Measurement Range 0.1 – 100%
Measurement Uncert. ± 0.2%
Threshold Level Range
5012B
5016B
5017B
5018B
5019B
2 W - 400 Watts
0.25 W - 60 Watts
13 W - 1300 Watts
0.1 W - 25 Watts
2.6 W - 100 Watts
Level Set Accuracy As peak power uncert. + 2%
Temp, Operating –10 to +50 °C (+14 to +122 °F)
Temp, Storage –40 to +80 °C (–40 to +176 °F)
Mechanical Shock and
Vibration
MIL-PRF-28800F class 3
Humidity, Max 95% (non-condensing)
Altitude, Max 15,000 ft. (4,500 m)
Dimensions, Nominal 4.75” x 4.6” x 1.3”
(121 x 117 x 33 mm)
Weight, Max 1.2 lb. (0.55 kg)
Part
Name
Toxic or hazardous Substances and Elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr(VI))
Polybro-
minated
biphenyls
(PBB)
Polybro-
minated
diphenyl
ethers
(PBDE)
Copper
Alloy
XOO O OO
O: Indicates that this toxic or hazardous substance contained in all of the
homogeneous materials.
X: Indicates that this toxic or hazardous substance contained in at least one of
the homogeneous.