20
Crest Factor
RF Power Range 0.15 to 150 W average, 4 W
minimum peak
Measurement Uncert. Linear sum of peak and average
power uncertainty
Complementary Cumulative Distribution Function (CCDF)
Measurement Range* 0.1 to 100%
Measurement Uncert. ± 2%
Threshold Level Range 2 to 400 W peak
Level Set Accuracy As peak power uncert. + 2%
* Duty Cycle and CCDF read out dependent on display
method.
Physical and Environmental Specifications
Measurement Uncert. ± (6% of reading + 50/D mW)
a
a. Above 35 °C or below 15 °C add 3%
** Duty Cycle and CCDF read out dependent on display
method.
Temp, Operating –10 to +50 °C (+14 to +122 °F)
Temp, Storage –40 to +80 °C (–40 to +176 °F)
Mechanical Shock
and V
ibration
MIL-PRF-28800F class 3
Humidity, Max 95% (non-condensing)