26
Burst Average Power
Power Range 1.0 W – 25 W average
Burst Width 1 μs – 5 ms
Repetition Rate, Min 5 Hz (with 12 dB peak/average ratio)
Duty Cycle (D)** 0.02 to 1 (D = Burst Width / Period)
Measurement Uncert. ± (6% of reading + 8/D W)
a
a. Above 35 °C or below 15 °C add 3%
** Duty Cycle and CCDF read out dependent on display
method.
Crest Factor
RF Power Range 25 mW to 25 W average
Measurement Uncert. Linear sum of peak and average
power uncertainty
Complementary Cumulative Distribution Function
(CCDF)
Measurement Range* 0.1 – 100%
Measurement Uncert. ± 2%
Threshold Level Range 25 mW to 60 W
Level Set Accuracy As peak power uncert. + 2%
* Duty Cycle and CCDF read out dependent on display
method.